HIL System for Electric & Hybrid Vehicle VCU Validation

SPECIFICATIONS / FEATURES
Pressure control solenoids used to manage pneumatic brake pressure via electrical control.
Data acquisition of temperature and current through NI hardware.
Graphical representation of performance for solenoid DUTs.
Automated ON/OFF control signals for solenoid operation.

Application Summary

TMCS developed a Hardware-in-the-Loop (HIL) system to validate Vehicle Control Units (VCUs) for electric and hybrid vehicles. Built with NI PXIe, LabVIEW and NI VeriStand for real-time simulation, the system performs CAN, I/O, load and calibration tests under automated control, ensuring reliable, highperformance VCU validation under simulated conditions.
Author: TMCS Team | Theta Measurement And Control Solutions Pvt. Ltd.

CHALLENGE

The VCU coordinates the powertrain, energy management and driver commands, so a fault in its software or I/O affects the whole vehicle. Testing it on prototypes is expensive and late in the program, and many conditions are hard or unsafe to create on a real vehicle. The challenge was to give the VCU a realistic electrical and network environment, with real-world loads and controlled faults, and to run the tests automatically and repeatably.

SOLUTION

TMCS built a layered VCU HIL system. The VCU connects through its harness to a front end that provides
fault insertion, loads that simulate real-world conditions and signal conditioning. NI PXIe DAQ hardware
handles analog, digital and CAN I/O while real-time models in NI VeriStand simulate the vehicle. The
LabVIEW software layer provides the user interface, automated test control and data logging.

Test Types / Parameters Monitored

TEST TYPE DESCRIPTION / PARAMETERS MONITORED
CAN Communication
Verifies VCU messages, signals and timing on the vehicle network
I/O Validation
Checks analog and digital inputs and outputs against expected behaviour
Load Testing
Validates VCU outputs while driving simulated real-world loads
Calibration Testing
Verifies calibration parameters and their effect on VCU behaviour
Fault Handling
Confirms VCU response to inserted electrical faults

Specifications & Features

Feature Description
Real-Time Simulation
Vehicle and powertrain models executed in NI VeriStand
Fault Insertion
Controlled electrical faults on VCU lines
Real-World Loads
Load simulation with front-end signal conditioning
Automated Control
Test execution and sequencing under software control
Data Logging
Structured logging for traceability and analysis

Technology Used

The system uses NI PXIe hardware for high-speed I/O and CAN interfacing. NI VeriStand runs the real-time vehicle models and LabVIEW provides the user interface, test control and data logging. Fault insertion, load simulation and signal conditioning in the front end connect the hardware safely to the VCU.

Advantage / Benefit

  • Early validation: VCU software and hardware are tested before vehicles are available.
  • Realistic conditions: real-world loads and network traffic exercise the VCU as in the vehicle.
  • Safe fault testing: electrical faults are injected without risk to vehicles or people.
  • Automated and repeatable: consistent regression testing with full data logging.
  • Supports EV and hybrid platforms: one architecture serves both.

Conclusion and Future Plan

The HIL system gives the customer a reliable, high-performance platform for VCU validation under simulated conditions. Future enhancements may include expanded fault scenarios, additional vehicle networks and closer integration with model-based development tools.

Powered by